Revising Organic Vapour Respirator Cartridge Change Schedule: a Case Study of a Paint Plant in Iran

Authors

  • Ali Karimi
    • Mehdi Jahangiri
      • Forough Zare Derisi
        • Mohammad Amin Nourozi

          DOI:

          https://doi.org/10.2478/10004-1254-64-2013-2256

          Keywords:

          chemical cartridge, NIOSH, odour threshold, service life

          Abstract

          After having revised the change schedule for organic vapour respirator cartridges in a paint plant in Iran, we established that it did not provide adequate protection against organic vapours at some workplaces and needed shortening from (48 to 72) h to 4 h. The revision also showed that relying on odour thresholds as the primary means to determine the time to change a chemical cartridge was not effective and that the National Institute for Occupational Safety and Health (NIOSH) MultiVapor service life software program could be applied to develop cartridge change schedules adjusted to specific workplaces.

          Downloads

          Published

          20 March, 2013

          Issue

          Section

          Professional paper

          How to Cite

          1.
          Karimi A, Jahangiri M, Derisi FZ, Nourozi MA. Revising Organic Vapour Respirator Cartridge Change Schedule: a Case Study of a Paint Plant in Iran. Arh Hig Rada Toksikol [Internet]. 2013 Mar. 20 [cited 2026 Oct. 13];64(1). Available from: https://arhiv.imi.hr/index.php/arhiv/article/view/35